Product Details
The ignition module features an automatic three-tries service with a pre-purge time of 0 seconds, an inter-purge time of 15 seconds, and an ignition time of 25 seconds. It operates on an input of 24 VAC at 50/60 Hz and requires 300 mA. The pilot valve operates at 24 VAC with a maximum of 2.0 A, while the main valve also operates at 24 VAC with a maximum of 2.0 A. Designed for a wide ambient temperature range of -40°F to +176°F, this module is compatible with a variety of Garland models, including CG-24R, CG-36R, CG-48F, CG-48R, CG-60F, CG-60R, CG-72F, CG-72R, GAW-24, GAW-36, GAW-48, GAW-60, and GAW-72.