Product Details
Springer Controls manufactures a complete line of IEC enclosed AC motor starters up to 60HP or 80A. Assembled motor starters consist of a contactor, overload relay, and a NEMA 4X rated polycarbonate enclosure. To select the proper starter, verify the full load amperage (FLA) at the input voltage from the motor or equipment nameplate, ensuring the correct phase power. Choose a starter rated for current higher than the FLA, select the control power for the contactor, and choose the overload by selecting a current range that includes the FLA. Additional criteria include incoming power options such as a "direct-online starter," "separate control voltage," or configurations with "remote start terminals" for activation from an external switch. The motor starter features include 9A rating, 1 phase operation, separate coil voltage with a reset button, 100-250V AC/DC coil voltage, 1.7-2.3A overload protection, and a NEMA 4X polycarbonate enclosure.